TexRib Information
TEX-RIB ALLOWABLE LOAD (PSF)* |
|
POSITIVE WIND LOAD |
LIVE LOAD |
DEFLECTION (IN) |
Ga. |
KSI |
2' |
2.5' |
3' |
4' |
5' |
6' |
2' |
2.5' |
3' |
4' |
5' |
6' |
2' |
2.5' |
3' |
4' |
5' |
6' |
29 |
80 |
158 |
101 |
70 |
36 |
19 |
11 |
118 |
76 |
53 |
27 |
14 |
8 |
0.11 |
0.17 |
0.24 |
0.40 |
0.50 |
0.60 |
26 |
80 |
206 |
132 |
92 |
48 |
25 |
14 |
155 |
99 |
69 |
36 |
18 |
11 |
0.11 |
0.17 |
0.24 |
0.40 |
0.50 |
0.60 |
26 |
50 |
134 |
86 |
59 |
33 |
21 |
15 |
100 |
64 |
45 |
25 |
16 |
11 |
0.07 |
0.11 |
0.15 |
0.27 |
0.42 |
0.60 |
24 |
80 |
263 |
168 |
117 |
61 |
31 |
18 |
197 |
126 |
88 |
46 |
23 |
14 |
0.11 |
0.17 |
0.24 |
0.40 |
0.50 |
0.60 |
24 |
50 |
170 |
76 |
76 |
43 |
27 |
19 |
128 |
82 |
57 |
32 |
20 |
14 |
0.07 |
0.10 |
0.15 |
0.27 |
0.42 |
0.60 |
NOTES:
- Allowable uniform loads are based upon
3 equal span lengths.
- Positive Wind is wind pressure
and is increased by 33 1/3%.
- Live is the allowable
live or snow load.
- Deflection is actual deflection
when loaded with the corresponding live load.
- The weight
of the panel has not been deducted from the allowable
loads.
- Web crippling has not been checked for the allowable
loads
shown above.

TEX-RIB SECTION PROPERTIES |
|
TOP IN COMPRESSION |
BOTTOM IN COMPRESSION |
Panel
Gauge |
Weight
PSF |
KY
KSI |
Ix
IN.4 |
Se
IN.3 |
Ma
KIP IN. |
Ix
IN.4 |
Se
IN.3 |
Ma
KIP IN. |
29 |
0.71 |
80 |
.0091 |
.0134 |
0.670 |
.0050 |
.0119 |
.0568 |
26 |
0.90 |
80 |
.0117 |
.0188 |
0.901 |
.0069 |
.0155 |
.0743 |
26 |
0.90 |
50 |
.0117 |
.0188 |
0.563 |
.0076 |
.0161 |
.0482 |
24 |
1.12 |
80 |
.0143 |
.0231 |
1.108 |
.0093 |
.0197 |
.0946 |
24 |
1.12 |
50 |
.0149 |
.0231 |
0.692 |
.0103 |
.0205 |
.0614 |
The Tex-Rib profile is one of the most wellsuited
designs for both commercial and industrial
use. It has also shown tremendous
growth in popularity as a residential roofing
panel.
* Oil canning is a natural occurance in metal and is
not cause for panel rejection. |